- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources4
- Resource Type
-
0000000004000000
- More
- Availability
-
40
- Author / Contributor
- Filter by Author / Creator
-
-
Dogariu, Arthur (4)
-
Ju, Yiguang (3)
-
Chen, Timothy Y (2)
-
Kolemen, Egemen (2)
-
Liu, Ning (2)
-
Morozov, Anatoli (2)
-
Chen, Timothy_Y (1)
-
Goldberg, Benjamin M (1)
-
He, Zichen (1)
-
Kliewer, Christopher_J (1)
-
Kondratowicz, Christopher (1)
-
Mao, Xingqian (1)
-
McCord, Walker (1)
-
Mei, Bowen (1)
-
Miles, Richard B (1)
-
Rousso, Aric C (1)
-
Shi, Zhiyu (1)
-
Wang, Ziyu (1)
-
Wu, Shuqun (1)
-
Xu, Yijie (1)
-
- Filter by Editor
-
-
null (1)
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
He, Zichen; McCord, Walker; Dogariu, Arthur; Morozov, Anatoli; Zhang, Zhili (, AIP Advances)The frame rate of conventional high-speed imaging devices is limited by exposure time and signal read-out time. Structured imaging is able to push the frame rate beyond the limit of the imaging device. This work demonstrates the feasibility of potential TeraHz rate structured imaging with a multiplexed structured imaging setup. In this work, a multiplexed structured image capture system was employed to image UV laser induced krypton-II emission lines at 10 GHz. The measured emission intensity of the 764 nm line over time suggests a temporal resolution of 97 ps. The temporal resolution is adjustable, and the frame rate can be further increased to the TeraHz level.more » « less
-
Chen, Timothy_Y; Liu, Ning; Kliewer, Christopher_J; Dogariu, Arthur; Kolemen, Egemen; Ju, Yiguang (, Optics Letters)We report the development of a simple and sensitive two-beam hybrid femtosecond/picosecond pure rotational coherent anti-Stokes Raman scattering (fs/ps CARS) method to simultaneously measure the rotational and vibrational temperatures of diatomic molecules. Rotation–vibration non-equilibrium plays a key role in the chemistry and thermalization in low-temperature plasmas as well as thermal loading of hypersonic vehicles. This approach uses time-domain interferences between ground state and vibrationally excited N2molecules to intentionally induce coherence beating that leads to apparent non-Boltzmann distributions in the pure rotational spectra. These distortions enable simultaneous inference of both the rotational and vibrational temperatures. Coherence beating effects were observed in single-shot fs/ps CARS measurements of a 75 Torr N2DC glow discharge and were successfully modeled for rotational and vibrational temperature extraction. We show that this method can be more sensitive than a pure rotational fs/ps CARS approach using a spectrally narrow probe pulse. Lastly, we experimentally measured the beat frequencies via Fourier transform of the time-domain response and obtained excellent agreement with the model.more » « less
-
Rousso, Aric C; Goldberg, Benjamin M; Chen, Timothy Y; Wu, Shuqun; Dogariu, Arthur; Miles, Richard B; Kolemen, Egemen; Ju, Yiguang (, Plasma Sources Science and Technology)null (Ed.)
An official website of the United States government
